  • Current-Voltage Measurement System

    Sciencetech, Inc.

    Sciencetech''s IV Testers are electrical current-voltage measurement systems used to characterize photovoltaic cell performance. This current-voltage tester works by sampling various current versus voltage combinations of the photovoltaic cell with a variable impedence load.This IV Test system can measure electrical power from photovoltaic cells up to 20W. The voltage envelope is limited to 20V and the current to 1A. A higher power version, up to 60W, is available. In general, the limitation on this model is the 1A current limit: if your solar cell generates more than 1A, we recommend upgrading to the 60W version.

  • PXIe-1086, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis

    781720-01 - NI

    PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis - The PXIe‑1086 incorporates hot-swappable, redundant AC power supplies as well as hot-swappable, front-accessible, redundant cooling fans. These high-availability features improve the mean time between failure (MTBF) and mean time to repair (MTTR) of the PXI system. The PXIe‑1086 monitors power supply health/voltages, air intake temperature, and fan health/speed; it provides any failure feedback with the status LEDs located on the chassis. This chassis is ideal for test, measurement, and control applications with demanding system uptime requirements.

  • PXIe-4136, 200 V, 1 A System PXIe Source Measure Unit

    783760-01 - NI

    ±200 V, 1 A System PXI Source Measure Unit—The PXIe‑4136 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4136 features 4-quadrant operation. The PXIe‑4136 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.

  • PXIe-4138, 60 V, 3 A System PXI Source Measure Unit

    782856-01 - NI

    ±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.

  • 100GBASE LR4/ER4 Wavelength Selective Power Meter

    KI6512 - Kingfisher International

    KI6512 is an easy and economical handheld 100GBASE LR4/ER4 Wavelength Selective Power Meter for testing multi-λ single mode fiber optic systems. It scans and stores the absolute or relative power levels of all 4 channels in 0.8 seconds. Test data can be viewed in graphical or numerical form, and reference values can be stored for easy loss testing. An extra 50/125u power meter port gives additional flexibility at 850 / 1300 / 1550 nm. This port only supports basic functions, but is very handy for first-in fault finding and investigation.

  • Nuclear EMC Testing Services

    Washington Laboratories LTD.

    The implementation of digital control and monitoring systems in nuclear power plants drives EMC requirements for new and replacement equipment to be used in nuclear plants. For the past 20 years, the Electric Power Research Institute (EPRI) has been developing test methods to demonstrate compliance with EMC requirements. The methods and limits are called out in EPRI TR-102323. The first issue of this report was released in 1994 and the current revision (Revision 4) was released in 2013. The original report and basis included results from electromagnetic surveys at seven nuclear power plants in the United States.

  • MLDD 4-Way Power Dividers

    KRYTAR, Inc.

    KRYTAR MLDD 4-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 4-way power dividers can also be manufactured to meet military specifications.

  • MLDD 8-Way Power Dividers

    KRYTAR, Inc.

    KRYTAR MLDD 8-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 8-way power dividers can also be manufactured to meet military specifications.

  • Exploratory Testing

    Worksoft

    Exploratory testing traditionally has been all about the people and not the tools. Free from dependency on requirements or test cases, exploratory tests can be performed much earlier in the QA process. Power users apply their deep knowledge of a system within a given time block to identify defects that script-based testing will miss. Targeted defects include incorrect requirements or the inability for a user to navigate a UI. While this activity can catch defects other tests miss, the value of exploratory testing has traditionally been limited for several reasons:

  • LED Driver Aging Rack

    LEDRACK-100W192P - Lisun Electronics Inc.

    • Application range: LED driver and multi channel driver power aging. It has equipped with computer operation and monitor system. The working condition can be set by the computer, and the computer will record real time data to do statistical analysis. • The parameters of load can be set freely on the software, to monitor the real time voltage, current, and power etc • Load mode: CC, CV, CR, CP, and LED • Aging Control System includes: ON/OFF control signal output; Signal of relay switch control; K type thermocouple temperature acquisition • The channels are parallel connected under arbitrary load mode, which can allow product power expansion • The LED Driver Aging rack will design according to customer’s LED driver power and aging quantity per time • Automatic current switching function (optional) • AC power meter to measure modules, and test power input characteristics (optional) • Temperature monitoring function at product zone (optional) • PWM dimming and two sets of logic control signal function (optional)

  • DC Standard Load Banks

    Ohm Loads Powertek Inc.

    The DC SERIES load banks are designed for connection to DC Power Supplies , Aircraft Power Converters, Telecom Rectifiers, Batteries, Fuel Cells or any other DC power source. The DC SERIESis ideal for integration into racked test systems or bench - top testing. These standard models are easily configured for other voltage and current ratings.

  • High-Power PXI Switch Matrix Modules

    Pickering Interfaces Ltd.

    These high-power PXI switch matrix modules provide higher current and power ratings than the high-density switch versions. These modules are designed for the switching of AC or DC loads or for controlling large relay or solenoid systems. The solid state relay matrices occupy two PXI slots and are suitable for automotive and aerospace test applications.

  • Powered VME430 Crates

    6U VME430 6021 - W-IE-NE-R, Plein & Baus GmbH

    The WIENER VME 6021 crate series is the newest generation of 19" integrated packaging system according to the CERN VME430 standard. Designed primarily for applications in nuclear and high energy physics data acquisition, beam line control and test instrumentation it combines superior mechanical quality with lowest noise power supply technology.

  • Powered VXS Crates

    6U VXS 6021 - W-IE-NE-R, Plein & Baus GmbH

    The WIENER VXS 6023 crate series adds high performance Switch Fabrics according to VITA 41 specification to VME based systems. Designed primarily for high speed applications in data acquisition, as well as military / aerospace test and instrumentation it combines superior mechanical quality with lowest noise power supply technology.

  • Powered VXS Crates

    6U VXS 6023-JL - W-IE-NE-R, Plein & Baus GmbH

    The WIENER VXS 6023 crate series adds high performance Switch Fabrics according to VITA 41 specification to VME based systems. Designed primarily for high speed applications in data acquisition, as well as military / aerospace test and instrumentation it combines superior mechanical quality with lowest noise power supply technology.